• Freezing Point (1℃-4℃) Chiller
Freezing Point (1℃-4℃) Chiller
Freezing point chiller: As the name implies, freezing point chiller means that the outlet water temperature of the chiller can be close to 0 degrees. The freezing point chiller developed by Dawosi's scientific and technological personnel does not need to add any antifreeze when the outlet water temperature is 1-2℃. Compared with the traditional unit, which needs to add antifreeze when the temperature is below 5℃, the application scenario is greatly improved. It is widely used in agricultural cleaning links, such as fruit and vegetable cleaning, poultry cleaning, seafood cleaning, and some special needs that require application to 1-2℃...
  • Product Detail
  • Product Tags

 Near Freezing Point (1℃-4℃)  Cold Water Chilling Solution

 

The 1℃ low-temperature chiller system developed by Davosi Organization Company does not require any antifreeze medium when the outlet water temperature is 1℃. Compared with the traditional chiller, which needs to add antifreeze when the temperature is below 5℃, the application scenario is greatly improved. It is widely used in agricultural cleaning links such as fruit and vegetable cleaning, poultry cleaning, and seafood cleaning. Some special scenarios that need to be applied to 1℃ are as follows: For these dairy processors, everyone has strict requirements for refrigeration equipment and facilities: high requirements for temperature control, high requirements for unit stability, high requirements for heat exchange medium, and high standards for the intelligence of the machine room.

 

1°C Constant Cold Water Solution


The chilled water system unit sends qualified chilled water into the water supply tank, which is then pumped to the terminal scene for use through an external circulation pump, and then returned to the unit through the return water tank to complete the cycle. The chilled water supply tank and return water tank are set up to weaken the impact of the terminal load mutation on the refrigeration unit and play a buffering and protective role for the water tank. The chilled water system uses a direct connection between the pump and the machine to optimize and reduce the pipeline resistance.


Technical features

1. Multiple refrigeration forms

It includes process ice water system, cooling water system, process cooling water system and process tower system.


2. Fine-grained control

Centralized management and control of the cold source room is achieved, and unmanned energy stations, semi-automatic energy-saving control, and fully automatic energy-saving control are realized; active and precise adaptive control technology is adopted, based on accurate control of 0.5℃, to achieve precise adaptation between the automatic control system and the host.

 

3. Water temperature fluctuations are stable

To ensure system stability, the outlet water temperature of process ice water is always lower than 2.0℃, the temperature in the process ice water supply tank is always lower than 1.5℃, and the outlet water temperature of a single machine is always lower than 1.0℃. At the same time, an instant machine shutdown function is provided to provide a reliable process cooling source guarantee for the workshop.


4. Mechatronics modularization

In order to realize unmanned management, the unit, water pump, water tank, cooling tower, power distribution, monitoring, integrated wiring, etc. can be integrated into one, realizing the high integration of refrigeration, power supply and management components, greatly reducing the space of the machine room. The modules are flexibly assembled, the overall layout structure is simple and compact, the construction and installation are convenient, and it is easy to disassemble and transport, which greatly shortens the on-site construction and commissioning cycle, realizes the factory prefabrication of the refrigeration room, and brings more economic benefits to the owner.


near freezing point chart.png


Near-freezing point chiller application

 1. Poultry

 Cooling poultry carcasses during poultry processing is an important step in ensuring food quality. Cooling poultry carcasses in pre-cooling tanks can not only effectively inhibit the reproduction rate of microorganisms, but also improve the muscle tissue structure, promote the absorption and retention of water by the muscles, and improve the freshness and tenderness of the meat.

The carcass flows in the spiral pre-cooling tank in the opposite direction to the water. The poultry carcass cannot be cooled in water for a long time. Ice water below 2°C is required to quickly reduce the core temperature of the carcass to below 4°C. The lower the ice water temperature, the shorter the cooling time.


2. Fruits and vegetables

After harvesting, fruits and vegetables are processed for commercialization through selection, grading, cleaning, sterilization, waxing, preservation, and fine packaging. Pre-cooling is a very important link. After harvesting, fruits and vegetables still have vigorous respiration, which will generate a lot of respiratory heat, which is not conducive to the storage and transportation of fruits and vegetables. Therefore, lowering the temperature of fruits and vegetables as soon as possible can not only reduce their physiological metabolic rate, but also inhibit the growth and reproduction of microorganisms, and reduce rot and deterioration during storage and transportation.

Soak the packed fruits and vegetables in running water or spray them. The product is suitable for precooling cherries, lychees, corn, carrots, etc.


主站蜘蛛池模板: 黄色国产在线观看 | 亚洲一区二区三区福利在线 | 国内精品一区二区在线观看 | 99热播 | 亚洲人成影院在线高清 | 国产又粗又黄又湿又大 | 色久激情 | 亚洲成a人不卡在线观看 | 亚洲国产精品一区二区三区久久 | 国产xvideos国产在线 | 欧美一级大片免费观看 | 久久精品国产99久久99久久久 | 2000xxxxav影院| 久久青草国产手机看片福利盒子 | 欧美一级高清片欧美国产欧美 | 在线观看免费国产成人软件 | a大片久久爱一级 | 成人91在线 | 免费一区二区三区在线视频 | 国产精品路边足疗店按摩 | 久久影院国产 | 成人交性视频免费看 | 一级欧美在线的视频 | 精品国产综合区久久久久久 | 9191久久久久视频 | 欧美精品久久天天躁 | 亚洲依依成人综合在线网址 | 手机看片久久高清国产日韩 | 欧美一做特黄毛片 | 在线一区播放 | 国产在线a不卡免费视频 | 特色一级片| 美女叉开腿让男人捅 | 一级毛片观看 | 天天欲色成人综合网站 | 99精品国产在热久久 | 亚洲网视频 | 久久有这有精品在线观看 | 日韩午夜在线观看 | 曰韩美女一级视频 | 成人午夜大片免费7777 |